Skip to main content

DS240 - DS246

DS240 - DS246 - BG230

Certified Safety Monitors with SinCos Encoder for Speed, Standstill, Direction of Rotation, Slip, & Shaft Fracture

 

The DS240 - 246 series devices are designed to connect to a SIL3/PLe certified sine cosine encoder or sensor. The DS240 is equipped with a relay, 4 transistor outputs, an analogue output and a signal distributor. The DS246 is an alternative version without a signal splitter.

 

Features

  • SIL3 and PLe certification
  • Safety functions equivalent to EN61800-5-2 (SS1, SS2, SOS, SLS, SDI, SSM)
  • Suitable for the connection with SIL3/PLe certified Sine-Cosine sensors or
    SinCos encoders with 1 Vpp (format sin+, sin-, cos+, cos-)
  • Two inverse redundant HTL / PNP inputs for encoders, proximity switches, and control commands (10 - 30V)
  • Extremely large bandwidth of 500 kHz
  • Forced guided redundant output relay (NO). Beside device errors, more alarm states can freely be parameterized (over- and under-speed, direction of rotation, standstill)
  • The function of the four inverse redundant digital outputs is also free programmable
  • Safe analog output with 4-20 mA for transmitting of proportional control loop values
  • Easy and safe integration into existing sensor wirings enabled by the integrated signal splitter
  • Fast and intuitive parameter setup by using the free service software or by using the BG230 programming module (optional)
  • Snap-on module for standard DIN rails (35 mm C-profile)

Additional Product Information