DM221/DM222: Strain Gauge Amplifier >>> Analog

DM221: one strain gauge input and one analog output

DM222:  two strain gauge inputs and two analog outputs

Strain gauge measuring amplifiers are used to transfer measured values from force sensors and load cells externally into analog signals. Measuring amplifiers are therefore used in many areas, such as in hydraulic presses, rolling machines, bending machines and strength testing machines. In addition to the measuring amplifiers, a strain gauge indicator from our touchMATRIX® series is also available.

Technical data

  • 6-wire connection for two independent strain gauge full bridge sensors
  • 4 control inputs [HTL/PNP]
  • 4 control outputs for signaling different operation states
  • Power supply 18 ... 30 VDC
  • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
  • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
  • Sensitivity of the sensor inputs 1 ... 10 mV
  • Transmission of the sensor data via RS485
  • Programming via USB and the user interface OS (freeware)
  • Protection class IP20
  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)